Engine Cross Reference

Generator Engine Model Cross Reference 8–4,000 kVA

Search, filter, and compare engine models across Cummins, Perkins, Weichai, and Yuchai matched to 8–4,000 kVA gensets. Identify the engine in your generator, compare options, and download the complete cross reference chart as Excel, CSV, or PDF.

Cummins · Perkins · Weichai · Yuchai
Engine model lookup
Parts & filter matching
Search & Filter Database
Download the complete cross reference chart as Excel, CSV, or PDF.
Shandong Huali

Factory‑Direct Genset Manufacturer

Diesel gensets from 8 to 4,000 kVA on Cummins, Perkins, Weichai, and Yuchai engines. ISO9001, CE, CCC certified.

25+Years experience
8–4,000kVA range
4Engine brands
Engine Cross Reference

What Is a Generator Engine Model Cross Reference?

A lookup table that connects a generator set model to the engine model installed inside it — and the reverse. It maps the genset model to the engine model so you can identify, compare, and source parts correctly across Cummins, Perkins, Weichai, and Yuchai.

Identify Confirm What You Have

Find out exactly which engine is in a set you already own. Match the genset model or the engine stamp to the cross reference table.

Compare Options at Every kVA

See which engine options deliver the same kVA in a new build. Compare Cummins, Perkins, Weichai, and Yuchai side by side.

Service Parts & Maintenance

Match filters, injectors, and service kits to the correct engine family. The cross reference connects to the parts table.

Why This Mapping Is Hard to Find

Engine manufacturers like Cummins and Perkins publish detailed catalogs of their own engines, but no single source maps generator set models to engines across multiple brands. A fleet with mixed brands, or a buyer comparing a Cummins option against a Weichai option, has to open four separate catalogs and align them by kVA. That is the gap this page closes — and the reason we publish a downloadable cross reference chart rather than a static article.

Built for Engineers & Maintenance Teams

One Database, Four Engine Brands

01
Full 8–4,000 kVA Range

Every kVA band from small home backup to large data center and industrial prime power.

02
Four Major Brands

Cummins, Perkins, Weichai, and Yuchai — the engines Huali fits across the full range.

03
Searchable & Filterable

Filter by brand, by kVA band, or search for a genset model or engine model. Instant results.

04
Downloadable Chart

Export the full cross reference as Excel, CSV, or PDF. Keep it with your equipment documents.

Searchable Database

Generator Engine Model Cross Reference: Searchable Database

Filter by engine brand, by kVA range, or search for a genset model or engine model. The tool returns the matching engine options for each build. The full dataset covers the complete 8 to 4,000 kVA mapping across all four brands.

Showing 44 matches
8–30 kVA — Small Backup & Residential
BrandEngine ModelDisplacementCyl.AspirationGovernorStandby kVAPrime kVA
Cummins4B3.9 / 4BT3.93.9 L4TurbochargedMechanical8–156–12
Perkins403D-11 / 404D-221.1–2.2 L3–4Naturally AspiratedMechanical8–156–12
WeichaiWP2.1 / WP3.22.1–3.2 L4TurbochargedElectronic8–156–12
YuchaiYC4A / YC4D4.2–4.8 L4TurbochargedMechanical8–156–12
Cummins4BT3.9-G13.9 L4TurbochargedMechanical20–3016–24
Perkins1103A-33G3.3 L4TurbochargedMechanical20–3016–24
WeichaiWP4.14.1 L4TurbochargedElectronic20–3016–24
YuchaiYC4D4.2 L4TurbochargedMechanical20–3016–24
40–120 kVA — Small Commercial & Light Industrial
BrandEngine ModelDisplacementCyl.AspirationGovernorStandby kVAPrime kVA
Cummins4BTA3.9-G2 / 6BT5.93.9–5.9 L4–6TurbochargedMechanical40–6032–48
Perkins1104A-44TG14.4 L4TurbochargedMechanical40–6032–48
WeichaiWP66.2 L6TurbochargedElectronic40–6032–48
YuchaiYC6B6.5 L6TurbochargedMechanical40–6032–48
Cummins6BT5.9-G1 / 6CT8.35.9–8.3 L6TurbochargedMechanical80–12064–96
Perkins1104A / 1106A4.4–6.6 L4–6TurbochargedMech / Elec80–12064–96
WeichaiWP6 / WP76.2–7.2 L6TurbochargedElectronic80–12064–96
YuchaiYC6J6.5 L6TurbochargedMechanical80–12064–96
150–330 kVA — Commercial & Industrial Prime
BrandEngine ModelDisplacementCyl.AspirationGovernorStandby kVAPrime kVA
Cummins6CTAA8.3-G28.3 L6TurbochargedMechanical150–200120–160
Perkins1106A-70TAG26.6 L6TurbochargedElectronic150–200120–160
WeichaiWP10 / WP1210–12 L6TurbochargedElectronic150–200120–160
YuchaiYC6G / YC6K7.8–10.3 L6TurbochargedMech / Elec150–200120–160
Cummins6LTAA8.9 / NT8558.9–14 L6TurbochargedMechanical250–330200–264
Perkins1306C-E87TAG48.7 L6TurbochargedElectronic250–330200–264
WeichaiWP1313 L6TurbochargedElectronic250–330200–264
YuchaiYC6K10.3 L6TurbochargedElectronic250–330200–264
400–800 kVA — Heavy Industrial & Infrastructure
BrandEngine ModelDisplacementCyl.AspirationGovernorStandby kVAPrime kVA
CumminsNTA855-G714 L6TurbochargedMechanical400–500320–400
Perkins2206C-E13TAG212.9 L6TurbochargedElectronic400–500320–400
WeichaiWD series / 12M3312–33 L6–12TurbochargedElectronic400–500320–400
YuchaiYC6T / YC6C9.7–15 L6TurbochargedMech / Elec400–500320–400
CumminsKTA19-G319 L6TurbochargedMechanical600–800480–640
Perkins2506C15.2 L6TurbochargedElectronic600–800480–640
Weichai6160A16 L6TurbochargedElectronic600–800480–640
YuchaiYC6C15 L6TurbochargedElectronic600–800480–640
1,000–2,000 kVA — Data Center & Large Plant
BrandEngine ModelDisplacementCyl.AspirationGovernorStandby kVAPrime kVA
CumminsKTA38-GA38 L12TurbochargedElectronic1000–1250800–1000
Perkins2806C18.1 L6TurbochargedElectronic1000–1250800–1000
Weichai16M3333 L16TurbochargedElectronic1000–1250800–1000
YuchaiYC12V / YC16V20–27 L12–16TurbochargedElectronic1000–1250800–1000
CumminsKTA50 / QSX6050–60 L16–18TurbochargedElectronic1500–20001200–1600
Perkins4006-23TAG2A23 L6TurbochargedElectronic1500–20001200–1600
Weichai12M3333 L12TurbochargedElectronic1500–20001200–1600
YuchaiYC16VC27 L16TurbochargedElectronic1500–20001200–1600
2,500–4,000 kVA — Ultra‑Large & Utility Scale
BrandEngine ModelDisplacementCyl.AspirationGovernorStandby kVAPrime kVA
CumminsQSK60 / QSK9560–95 L18–16TurbochargedElectronic2500–40002000–3200
Perkins4012 / 401623–32 L12–16TurbochargedElectronic2500–40002000–3200
Weichai16M3333 L16TurbochargedElectronic2500–40002000–3200
YuchaiYC16V / YC16VC27–32 L16TurbochargedElectronic2500–40002000–3200
Footnote: This is a representative generator engine cross reference, not a guarantee that every engine listed is fitted to every build in the band. Engine fitment depends on the alternator interface, the PTO, the radiator package, the governor, and the emission tier. For the exact configuration of a specific generator, refer to the full diesel generator specifications database or ask our engineers.
Quick Reference

Generator Engine Cross Reference Table: Cummins, Perkins, Weichai, Yuchai

Representative engine options for each kVA band across the four brands Huali fits. Ratings are standby / prime for 50 Hz genset builds.

kVA Band Cummins Perkins Weichai Yuchai
8–15 4B3.9 / 4BT3.9 403D-11 / 404D-22 WP2.1 / WP3.2 YC4A / YC4D
20–30 4BT3.9-G1 1103A-33G WP4.1 YC4D
40–60 4BTA3.9-G2 / 6BT5.9 1104A-44TG1 WP6 YC6B
80–120 6BT5.9-G1 / 6CT8.3 1104A / 1106A WP6 / WP7 YC6J
150–200 6CTAA8.3-G2 1106A-70TAG2 WP10 / WP12 YC6G / YC6K
250–330 6LTAA8.9 / NT855 1306C-E87TAG4 WP13 YC6K
400–500 NTA855-G7 2206C-E13TAG2 WD series / 12M33 YC6T / YC6C
600–800 KTA19-G3 2506C 6160A YC6C
1,000–1,250 KTA38-GA 2806C 16M33 YC12V / YC16V
1,500–2,000 KTA50 / QSX60 4006-23TAG2A 12M33 YC16VC
2,500–4,000 QSK60 / QSK95 4012 / 4016 16M33 YC16V / YC16VC
Footnote: This is a representative generator engine cross reference, not a guarantee that every engine listed is fitted to every build in the band. Engine fitment depends on the alternator interface, the PTO, the radiator package, the governor, and the emission tier. For the exact configuration of a specific generator, refer to the full diesel generator specifications database or ask our engineers.
How to Use This Guide

How to Find the Engine Model & Understand Interchangeability

Identify the engine in your generator, understand how model numbers map, and learn what can — and cannot — be swapped between brands.

01

Find the Engine Model

Start with the genset data tag on the frame or control cabinet. It lists the generator set model and the rated output. Note the genset model, because it identifies the set family and the kVA rating.

Next, find the engine model number stamped directly on the engine block. Common locations are the valve cover, the side of the block near the oil filter, or the blower housing on enclosed units.

02

Avoid the Emissions Number

Ignore the emissions family numbers on the engine label. They identify the emission family, not the engine model. The engine model you need follows the brand's naming convention, such as Cummins 6CTAA8.3-G2 or Perkins 1106A-70TAG2.

Example: A 250 kVA standby genset with an engine stamp reading NT855 — the cross reference confirms this is the Cummins option for the 250–330 kVA band.

03

Model Numbers to Engines

Generator model numbers usually encode the output rating, and the engine is a build option within that rating. In most genset naming, the digits identify the standby kVA, and the engine brand is a configuration choice, not part of the set identity.

A 200 kVA build for a European buyer might carry a Perkins 1106A, while the same frame for an African market might carry a Weichai WP12. The genset model stays the same — the cross reference tells you which power plant each build carries.

04

Parts Require the Engine Model

When ordering replacement parts, you must quote the engine model, not only the genset model. Filters, injectors, and service kits are engineered for the engine. A parts desk that only has the genset model cannot tell you the correct filter.

For Huali sets: The serial number on the data tag carries build information that identifies the engine fitted at the factory. Provide the serial number and our after-sales team can confirm the exact configuration.

05

Interchangeability & Swaps

Cross reference does not mean free swap. Within a kVA band, the engine options are alternative power plants for the same genset frame, but they are not bolt-in replacements for each other without re-engineering.

What must match: the duty rating, flywheel housing and SAE interface, PTO and governor, radiator and fan package, and emission tier. In practice, changing the engine inside an existing genset is rarely economical.

Because Huali fits all four brands, we can build the same output with the engine you prefer and the parts ecosystem you already stock.

Quick Reference

From Engine Stamp to Correct Parts

A site operator with a 250 kVA standby genset reads the engine stamp and finds NT855. The cross reference confirms this is the Cummins option for the 250–330 kVA band, and the parts section matches the NT855 family to its service kit reference.

If the stamp is unreadable, cross reference by genset model and kVA rating instead, then confirm the fitment with the supplier.

Final engine identification should be confirmed against the engine data plate and the generator specification sheet before ordering parts or replacement units. When in doubt, provide the set serial number to our after-sales team for a factory build record lookup.

Let's talk

Download the Complete Engine Cross Reference Chart

Get the full generator engine model cross reference in Excel, CSV, or PDF — every engine option from 8 to 4,000 kVA across Cummins, Perkins, Weichai, and Yuchai. Also receive a free factory-direct quote for the genset or replacement engine that fits your project.

Frequently Ask Questions

Get in touch with us
Leave a message